Insulation Resistance Testing Equipment for Hire
Day rates, 1 to 7 days, ex GST:
- Megger MIT515/2 5kV Insulation Resistance Tester$120
- Megger MIT1025/2 10kV Insulation Resistance Tester$135
Every rate band is on the instrument page. Minimum hire one day.
Rates per day, ex GST
Insulation Resistance Testing Equipment Available for Hire
Each instrument is supplied with its manuals. If one plays up, call us and we will arrange a fix or a replacement. No computer is supplied: where an instrument needs software, install it on your own computer.
Megger
Calibration
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Get a quote for insulation resistance testing equipment hire
Australia-wide delivery, current calibration, fault support. Most enquiries quoted same business day.
Tell us what you need and when, and we will come back with availability and pricing.
About insulation resistance testing equipment hire
Insulation Resistance Testing Equipment hire, in more detail
Introduction
Megavar supplies diagnostic insulation resistance testers for hire across Australia, supporting acceptance testing, commissioning verification, preventive maintenance, and fault investigation on high voltage cables, rotating machines, transformers, and switchgear. The hire fleet covers the Megger MIT range at two test voltages: the MIT 5 kV for the bulk of HV insulation diagnostics, and the MIT 10 kV for the highest voltage class assets and the most demanding diagnostic work. The same instruments are used by Megavar commissioning engineers on substation, BESS, and renewable energy projects every week.
Insulation resistance testing is the first line of evidence on the condition of electrical insulation. A simple spot reading confirms an asset is safe to energise, but the diagnostic value comes from the time-based tests that a high voltage insulation tester performs: the polarisation index, which compares the ten-minute reading to the one-minute reading, and the dielectric absorption ratio, which compares the sixty-second reading to the thirty-second reading. Both reveal moisture ingress and insulation ageing that a spot reading cannot. On HV plant the test voltage matters: insulation that passes at 1 kV can still fail under the stress of a 5 kV or 10 kV diagnostic test that approaches the conditions the insulation sees in service.
The Megavar insulation resistance hire fleet is built on the Megger MIT diagnostic range, the established high voltage insulation tester family in heavy use across Australian utilities, generators, and engineering firms. The instruments deliver guarded measurement to the tera-ohm range, programmable test voltages, automatic polarisation index and dielectric absorption calculation, dielectric discharge testing, and step-voltage and ramp-voltage modes for breakdown investigation. Test results store on the instrument and download to the Megger software for trend comparison against previous tests on the same asset, which is the basis of any condition-based maintenance programme. Hire from our offices in Hobart, Launceston, Adelaide and Newcastle, with delivery Australia-wide, from a team that performs insulation diagnostics as a regular part of substation commissioning, cable acceptance, and rotating machine maintenance scopes.
Insulation resistance testing applications and standards
The fleet supports the full range of HV insulation diagnostic scenarios across utility, industrial, generation, and renewable energy sites.
HV cable acceptance and maintenance testing
Insulation resistance testing is a standard step in cable acceptance and maintenance, performed alongside VLF withstand and tan delta diagnostics. The polarisation index and dielectric absorption tests detect moisture ingress at terminations and joints before it develops into a fault. The MIT 5 kV and 10 kV both perform timed PI and DAR tests automatically and store the full resistance-versus-time curve for analysis.
Rotating machine insulation diagnostics
Generator and large motor stator winding insulation is assessed by polarisation index at 5 kV or 10 kV depending on the machine voltage class, following IEEE 43 for the recommended practice. The guarded measurement terminal on the MIT range isolates the winding under test from surface leakage and end-winding current, which is essential for a meaningful PI on a large machine.
Transformer and switchgear insulation testing
Winding-to-winding and winding-to-earth insulation resistance on transformers, and phase-to-earth insulation on switchgear, are routine acceptance and maintenance measurements. The diagnostic test voltages and the dielectric discharge test on the MIT range distinguish genuine insulation degradation from temporary surface effects.
Commissioning verification on substation and renewable plant
Insulation resistance verification on primary plant, cables, and auxiliary systems is a normal hold point in substation, solar farm, wind farm, and BESS commissioning. Megavar engineers perform these tests as a regular part of commissioning scopes, which is why the hire fleet is maintained to commissioning standard.
Standards referenced
IEEE 43 (rotating machine insulation, polarisation index), IEEE C57.12.90 and IEEE C57.152 (transformers), IEEE C57.13.1 (CT secondaries), IEEE 400 (cables) and asset-specific IEC standards for the plant under test, and the relevant Australian network service provider commissioning specifications. Megavar can develop project-specific insulation test plans against the standards and acceptance values that apply to the asset.
When to Hire vs Buy
Diagnostic high voltage insulation testers carry a meaningful capital cost, an annual calibration cycle, and software that is periodically revised by the manufacturer.
Hire from Megavar when...
- You need a 5 kV or 10 kV diagnostic tester for a single acceptance, commissioning, or maintenance campaign
- Capital is constrained or the project rate does not justify outright purchase of a current-generation diagnostic tester
- Calibration and freight on owned equipment would exceed hire cost over the project life
- Your scope is short and the unit would otherwise sit idle between projects
Consider purchasing when...
- Your team performs HV insulation diagnostics on more than 60 days per year
- You have in-house test engineers competent on the PI, DAR, and dielectric discharge workflow
- You can amortise the unit over its 7 to 10 year service life
- Your asset programme commits to a multi-year insulation trend baseline
- You require permanent on-call availability that hire cannot guarantee
Why Hire from Megavar
Megavar is a specialist HV testing and commissioning firm with offices in Hobart, Launceston, Adelaide, Newcastle and Gladstone. We perform insulation diagnostics as a regular part of substation commissioning, cable acceptance, and rotating machine maintenance work for ElectraNet, TasNetworks, Downer, Acciona, Zinfra/Jemena, and renewable energy developers across Australia. The hire fleet exists because we built it for our own commissioning teams first, and we maintain it to the standard those teams require.
When you hire insulation resistance testing equipment from Megavar you receive: full current calibration with traceable certificates, the complete test and guard lead set, and a configuration tailored to your scope. Where the project demands a turnkey insulation diagnostic survey rather than equipment hire alone, we can quote on the full service. Hire periods are flexible from a single-day acceptance check through to multi-month maintenance campaigns. Delivery is Australia-wide. Call 1300 730 499 or email rentals@megavar.com.au.
Before you get to site
Insulation Resistance Testing: A Field Guide to Megger Testing, PI and DAR on HV Plant
A Megavar field guide to the test: what it proves, how it is set up and how to read the result.
Capability statement
Test Equipment Rental
The HV test equipment hire fleet by category, with calibration, hire terms and delivery.
How the hire works
Hire terms in brief
After you enquire
We confirm availability, rates and freight in a written quote, valid for the period it states (usually 14 days). An enquiry or quote does not reserve equipment: the hire is booked when your purchase order, signed quote or email acceptance reaches us.
Hire period
Our carrier: up to 72 hours of transit each way is not charged as hire. Hire starts at delivery or 72 hours after dispatch, whichever is earlier, and ends at handover to our carrier or 72 hours before the equipment arrives back, whichever is later. Delay caused by us or our carrier is not charged. For example, dispatched Monday 10am and delivered Wednesday 2pm: hire starts Wednesday 2pm. Routes that normally take longer than 72 hours are marked on the quote. Your own freight: hire runs from handover to your carrier at our office until the equipment arrives back at our office. Collect in person: from collection to return.
Extensions and early return
Contact us before the return deadline to extend; your quoted rates stay fixed and extended hire is invoiced every 7 days. Return early and you pay only for the days used, at the rate band for the days actually hired.
Delivery and returns
Freight for each leg, the handling fee and any express dispatch are on the quote, before you accept. Returns go to the dispatching office named on the quote, by carrier or in person, never by post.
Counter times
Returned to our counter before 9am on a business day counts as the previous day. Collected after 4pm on a business day, hire starts the next day. Weekends and public holidays count as hire days.
Calibration and checks
Supplied in working order with listed accessories, leads and manuals. Each measuring instrument is calibrated, and its current NATA-traceable calibration certificate is available on request. If calibration falls due during your hire, we tell you before dispatch.
Cancelling or moving a booking
Cancel 5 or more business days before dispatch or collection and nothing is charged. With 2 to 4 business days’ notice, the charge is the greater of one day’s hire and 5% of the booked hire; with less notice, the greater of one day’s hire and 10%. You can ask once to move the start by up to 30 days, with at least 2 business days’ notice.
Loss, damage and insurance
The equipment is your responsibility, other than fair wear and tear, from the start of hire until it is back with us, including in transit, up to the replacement value cap shown on the quote for each item. No damage waiver is offered. We recommend you insure the equipment for its replacement value.
Payment and bond
Account customers pay each invoice within 14 days. Without a credit account, or paying by card, you pay the booked hire, freight, handling fee and any bond before dispatch. A bond applies only where the quote states one, and is refunded after return and inspection, less anything owed.
Summary of our Terms and Conditions: Test Equipment Hire. Full hire terms
Enquire about Insulation Resistance Testing Equipment Hire
Check availability
Send your hire dates and delivery location and we will confirm availability and lead time by the end of the next business day.
Or call us directly on 1300 730 499
Need help with your rental?
1300 730 499 We’re available Monday to Friday, 8:30 am to 5:00 pm. Urgent hire: call rather than send the form. rentals@megavar.com.auFAQ
Frequently Asked Questions for Insulation Resistance Testing Equipment
What is an insulation resistance tester?
An insulation resistance tester, often called a megohmmeter or by the brand name Megger, applies a known DC test voltage across electrical insulation and measures the resulting leakage current to calculate insulation resistance. A diagnostic high voltage tester goes further than a simple spot reading by performing timed tests, the polarisation index and dielectric absorption ratio, and a dielectric discharge test, which reveal moisture ingress and insulation ageing that a single reading cannot. The Megavar fleet covers the Megger MIT diagnostic range at 5 kV and 10 kV.
What test voltage do I need for insulation resistance testing?
The test voltage should match the voltage class of the asset and the acceptance specification. Low voltage equipment is typically tested at 500 V or 1 kV, but HV cables, transformers, switchgear, and rotating machines are tested at 2.5 kV, 5 kV, or 10 kV so the diagnostic test approaches the stress the insulation sees in service. The Megavar fleet provides 5 kV and 10 kV diagnostic testers for HV plant.
What is a good insulation resistance value?
There is no single universal pass figure; acceptance depends on the asset type, its voltage class, temperature, and the applicable standard. The more meaningful diagnostic is the trend over time and the time-based ratios. A polarisation index above 2 generally indicates dry, sound insulation on a rotating machine per IEEE 43, while a value near 1 suggests moisture or contamination. Comparing the current result against previous tests on the same asset, corrected for temperature, is the basis of any condition assessment.
What is the polarisation index?
The polarisation index is the ratio of the insulation resistance measured at ten minutes to the resistance measured at one minute, during a continuous test at constant voltage. Sound, dry insulation continues to increase in resistance over the ten-minute period, giving a high ratio. Wet or contaminated insulation reaches a steady value quickly, giving a ratio close to 1. The Megger MIT range calculates the polarisation index automatically and stores the full resistance-versus-time curve.
What is the difference between a 5 kV and a 10 kV insulation tester?
The difference is the maximum diagnostic test voltage. The 5 kV unit covers the bulk of HV cable, transformer, switchgear, and motor insulation diagnostics. The 10 kV unit is required for the highest voltage class assets and large generator stator windings, where the acceptance specification or the asset voltage class calls for a 10 kV test so the diagnostic approaches in-service stress. Both units perform the same polarisation index, dielectric absorption, and dielectric discharge tests; the 10 kV simply extends the available test voltage.
What is a dielectric discharge test?
The dielectric discharge test measures the reabsorption current one minute after a timed insulation test is de-energised and the insulation is allowed to discharge. It is sensitive to ageing and deterioration in multi-layer insulation systems, particularly in cables and transformer windings, and detects problems that the polarisation index alone may miss. The Megger MIT diagnostic range performs the dielectric discharge test automatically as part of the diagnostic test sequence.
Why is the guard terminal important on an insulation tester?
The guard terminal diverts surface leakage current away from the measurement circuit, so the instrument measures only the volume resistance through the insulation rather than the combined volume and surface leakage. On a contaminated or humid surface, or on a large machine winding with significant end-winding leakage, guarding is essential for a meaningful result. The Megger MIT range provides a dedicated guard terminal.
Do you provide test engineers as well as the equipment?
Yes. Megavar performs full insulation diagnostic surveys using the equipment in this rental fleet, including test planning, on-site execution, result interpretation, and reporting against IEEE 43 and the relevant acceptance specifications. If your project requires a turnkey survey rather than equipment hire alone, contact us with the asset type, voltage class, the standard or specification that applies, and the test window, and we will quote a full scope.
Explore Rental Categories
Explore Our Services
Trusted by top enterprises for exceptional results



Testing guides
Related testing guides
Insulation Resistance Testing: A Field Guide to Megger Testing, PI and DAR on HV Plant
An insulation resistance test applies a steady DC voltage across insulation and measures the small current that flows. This guide explains the test voltage to use,…
Hipot Testing: A Field Guide to HV Withstand Testing of Switchgear, GIS and Bushings
Hipot testing applies a voltage well above the operating voltage to insulation for a set time to prove it withstands it. This guide explains AC, resonant…
Transformer Testing: The Commissioning and Diagnostic Tests, and What Each One Proves
Transformer testing covers a defined set of electrical, dielectric and oil tests that together prove a power transformer is fit to energise and track its condition…
Minimum hire one day View instruments