Equipment hire
Circuit Breaker Test Equipment for Hire
Day rates, 1 to 7 days, ex GST:
- Omicron CPX 200 for Hire Multifunctional Test Set$600
- Omicron HVX10 for Hire 10 kV High-Voltage Source$420
- Omicron CPC 100 Multi-Function Primary Test Set$550
- Omicron CIBANO 500 Circuit Breaker Test System$450
Every rate band is on the instrument page. Minimum hire one day.
Rates per day, ex GST
Omicron Equipment Available for Hire
Each instrument is supplied with its manuals. If one plays up, call us and we will arrange a fix or a replacement. No computer is supplied: where an instrument needs software, install it on your own computer.
Calibration
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Need High Voltage Testing or Equipment?
Tell us what you need and when, and we will come back with availability and pricing.
About circuit breaker test equipment hire
Circuit Breaker Test Equipment hire, in more detail
Introduction
Megavar supplies a full range of circuit breaker test equipment for hire across Australia, covering timing analysis, contact resistance measurement, motion analysis, and coil current testing for medium-voltage and high-voltage circuit breakers. Our circuit breaker testing fleet includes the Omicron CIBANO 500, a 3-in-1 circuit breaker test system (timing and travel analyser, micro-ohmmeter, and coil and motor supply in one unit), along with Megger’s TM1600 timing analyser and EGIL switching test set.
Circuit breaker testing is a critical part of substation commissioning and ongoing maintenance programmes. Megavar’s engineers perform circuit breaker testing on assets ranging from 11kV distribution switchgear through to 500kV transmission circuit breakers.
All circuit breaker test equipment is supplied calibrated, with test leads, connection accessories, and carry cases. Flexible hire periods and Australia-wide delivery are available.
Why Hire Circuit Breaker Test Equipment from Megavar?
Before you get to site
How to Test a Circuit Breaker: Timing, Travel and Coil Tests Explained
A Megavar field guide to the test: what it proves, how it is set up and how to read the result.
Capability statement
Test Equipment Rental
The HV test equipment hire fleet by category, with calibration, hire terms and delivery.
How the hire works
Hire terms in brief
After you enquire
We confirm availability, rates and freight in a written quote, valid for the period it states (usually 14 days). An enquiry or quote does not reserve equipment: the hire is booked when your purchase order, signed quote or email acceptance reaches us.
Hire period
Our carrier: up to 72 hours of transit each way is not charged as hire. Hire starts at delivery or 72 hours after dispatch, whichever is earlier, and ends at handover to our carrier or 72 hours before the equipment arrives back, whichever is later. Delay caused by us or our carrier is not charged. For example, dispatched Monday 10am and delivered Wednesday 2pm: hire starts Wednesday 2pm. Routes that normally take longer than 72 hours are marked on the quote. Your own freight: hire runs from handover to your carrier at our office until the equipment arrives back at our office. Collect in person: from collection to return.
Extensions and early return
Contact us before the return deadline to extend; your quoted rates stay fixed and extended hire is invoiced every 7 days. Return early and you pay only for the days used, at the rate band for the days actually hired.
Delivery and returns
Freight for each leg, the handling fee and any express dispatch are on the quote, before you accept. Returns go to the dispatching office named on the quote, by carrier or in person, never by post.
Counter times
Returned to our counter before 9am on a business day counts as the previous day. Collected after 4pm on a business day, hire starts the next day. Weekends and public holidays count as hire days.
Calibration and checks
Supplied in working order with listed accessories, leads and manuals. Each measuring instrument is calibrated, and its current NATA-traceable calibration certificate is available on request. If calibration falls due during your hire, we tell you before dispatch.
Cancelling or moving a booking
Cancel 5 or more business days before dispatch or collection and nothing is charged. With 2 to 4 business days’ notice, the charge is the greater of one day’s hire and 5% of the booked hire; with less notice, the greater of one day’s hire and 10%. You can ask once to move the start by up to 30 days, with at least 2 business days’ notice.
Loss, damage and insurance
The equipment is your responsibility, other than fair wear and tear, from the start of hire until it is back with us, including in transit, up to the replacement value cap shown on the quote for each item. No damage waiver is offered. We recommend you insure the equipment for its replacement value.
Payment and bond
Account customers pay each invoice within 14 days. Without a credit account, or paying by card, you pay the booked hire, freight, handling fee and any bond before dispatch. A bond applies only where the quote states one, and is refunded after return and inspection, less anything owed.
Summary of our Terms and Conditions: Test Equipment Hire. Full hire terms
Enquire about Circuit Breaker Testing Equipment Hire
Check availability
Send your hire dates and delivery location and we will confirm availability and lead time by the end of the next business day.
Or call us directly on 1300 730 499
Need help with your rental?
1300 730 499 We’re available Monday to Friday, 8:30 am to 5:00 pm. Urgent hire: call rather than send the form. rentals@megavar.com.auFAQ
Frequently Asked Questions for Circuit Breaker Test Equipment
What tests does the Omicron CIBANO 500 perform on circuit breakers?
Can I test both medium-voltage and high-voltage circuit breakers with your hire equipment?
What is circuit breaker contact resistance testing and why is it important?
How long does it take to set up the CIBANO 500 for a circuit breaker test?
Do you offer on-site circuit breaker testing services as well as equipment hire?
Explore Our Services
Trusted by top enterprises for exceptional results



Testing guides
Related testing guides
How to Test a Circuit Breaker: Timing, Travel and Coil Tests Explained
Circuit breaker testing confirms a breaker opens and closes on command, fast enough and with its poles together. This guide explains timing, pole spread, travel, coil…
Ductor Testing: A Field Guide to Contact Resistance Measurement on HV Plant
Ductor testing measures the resistance of circuit breaker contacts, busbar joints, cable lugs and earth bonds in micro-ohms. This guide explains the test current to use,…
Insulation Resistance Testing: A Field Guide to Megger Testing, PI and DAR on HV Plant
An insulation resistance test applies a steady DC voltage across insulation and measures the small current that flows. This guide explains the test voltage to use,…
Minimum hire one day View instruments