Equipment hire

Earth Testing Equipment for Hire

Day rates, 1 to 7 days, ex GST:

Every rate band is on the instrument page. Minimum hire one day.

Calibrated, NATA-traceable certificatesAustralia-wide delivery or collectionMinimum hire one daySupplied with manufacturer’s manuals
Need availability or a price? Call us on 1300 730 499 or send an enquiry.

Rates per day, ex GST

Earth Testing Equipment Available for Hire

Each instrument is supplied with its manuals. If one plays up, call us and we will arrange a fix or a replacement. No computer is supplied: where an instrument needs software, install it on your own computer.

Omicron CPC 100 Multi-Function Primary Test Set

The Omicron CPC 100 is a universal primary injection test system designed for high-precision testing of power transformers, CTs, VTs, circuit breakers…

$550/day, 1 to 7 days
$346.50/day for 29 to 90 days

AEMC 6471 Ground Resistance Tester

The AEMC 6471 is a multifunction ground resistance tester designed to measure ground resistance using 3-point, 4-point, selective, and stakeless testi…

$155/day, 1 to 7 days
$97.65/day for 29 to 90 days

Red Phase 4025E Frequency Selective Multimeter

The Red Phase 4025E Frequency Selective Multimeter is a precision instrument designed to measure voltage and current at a specific test frequency, typ…

$135/day, 1 to 7 days
$92/day for 29 to 90 days

Red Phase 4022C Continuity Tester

The Red Phase 4022C is a remote bonding continuity tester designed for verifying low-resistance connections in earthing systems, bonding conductors, a…

$155/day, 1 to 7 days
$97.65/day for 29 to 90 days

Red Phase 1.5 kVA Earth Current Injection Set (4024B + 4023)

The Red Phase 4024B + 4023 system is a compact, portable earth current injection test set designed for verifying the performance of substation earth g…

$475/day, 1 to 7 days
$299.25/day for 29 to 90 days

Mitton Instruments TVM1100 Tuned Voltmeter for Hire

The Mitton TVM1100 has been specifically designed to accompany the LCI2000C injection unit, though it can be used for the measurement of voltages asso…

$85/day, 1 to 7 days
$53.55/day for 29 to 90 days

PFISTERER CONNEX Grounding and Current Testing Connector (Size 0) for Hire

The PFISTERER CONNEX grounding and current testing connector, Size 0, allows current tests to be carried out on switchgear, transformers and transduce…

$60/day, 1 to 7 days
$37.80/day for 29 to 90 days

PFISTERER CONNEX Grounding and Current Testing Connector (Size 1) for Hire

The PFISTERER CONNEX grounding and current testing connector, Size 1, performs the same function as the Size 0 unit at a higher current rating of 630 …

$60/day, 1 to 7 days
$37.80/day for 29 to 90 days

Calibration

All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.

Need High Voltage Testing or Equipment?

Tell us what you need and when, and we will come back with availability and pricing.

rentals@megavar.com.au

About earth testing equipment hire

Earth Testing Equipment hire, in more detail

Introduction

Megavar provides earth testing equipment for hire across Australia, supporting earth grid impedance measurement, step and touch voltage assessment, ground electrode resistance testing, and soil resistivity surveys. Our earth testing fleet includes the Omicron CPC 100 + CP CU1 platform for comprehensive substation earth grid testing, AEMC 6471 portable ground resistance testers, and Red Phase high-current earth injection sets for large earth grid systems.

 

Earthing system performance is critical to personnel safety and protection system operation on electrical networks. Megavar’s engineers perform earth grid testing and commissioning for transmission and distribution network owners across Australia, from new substation builds to earth grid augmentation projects. When you hire earth testing equipment from us, you get access to engineers who understand the practical challenges of earth testing in the field, from managing long current injection leads at remote sites to interpreting results that indicate whether an earth grid meets the requirements of ENA EG-0 (risk framework), ENA EG-1 (Substation Earthing Guide), AS 2067:2016 and site-specific safety criteria.

All earth testing equipment is supplied calibrated and complete with test leads, current injection cables, and accessories appropriate for your testing scope. Flexible hire periods and Australia-wide delivery are available.

Why Hire Earth Test Equipment from Megavar?

Earth grid testing is one of Megavar's core competencies. Our engineers commission and test substation earthing systems for transmission and distribution network owners across Australia, so we know what works in the field. That includes managing several hundred metres of current injection lead at remote sites, and reading results that confirm compliance with ENA EG-0, ENA EG-1, AS 2067:2016 and individual NSP standards.

 

All earth testing kits are supplied calibrated, with appropriate test leads and current injection cabling sized to your earth grid dimensions. Where the test setup is complex or you want a second opinion on results, our engineers can support remotely or on site. We dispatch from offices in Hobart, Launceston, Adelaide, and Newcastle with delivery Australia-wide.

Before you get to site

Testing guide

Earth Resistance Testing: Substation Earth Grids, Fall of Potential and Step and Touch Voltages

A Megavar field guide to the test: what it proves, how it is set up and how to read the result.

Capability statement

Test Equipment Rental

The HV test equipment hire fleet by category, with calibration, hire terms and delivery.

How the hire works

Hire terms in brief

After you enquire

We confirm availability, rates and freight in a written quote, valid for the period it states (usually 14 days). An enquiry or quote does not reserve equipment: the hire is booked when your purchase order, signed quote or email acceptance reaches us.

Hire period

Our carrier: up to 72 hours of transit each way is not charged as hire. Hire starts at delivery or 72 hours after dispatch, whichever is earlier, and ends at handover to our carrier or 72 hours before the equipment arrives back, whichever is later. Delay caused by us or our carrier is not charged. For example, dispatched Monday 10am and delivered Wednesday 2pm: hire starts Wednesday 2pm. Routes that normally take longer than 72 hours are marked on the quote. Your own freight: hire runs from handover to your carrier at our office until the equipment arrives back at our office. Collect in person: from collection to return.

Extensions and early return

Contact us before the return deadline to extend; your quoted rates stay fixed and extended hire is invoiced every 7 days. Return early and you pay only for the days used, at the rate band for the days actually hired.

Delivery and returns

Freight for each leg, the handling fee and any express dispatch are on the quote, before you accept. Returns go to the dispatching office named on the quote, by carrier or in person, never by post.

Counter times

Returned to our counter before 9am on a business day counts as the previous day. Collected after 4pm on a business day, hire starts the next day. Weekends and public holidays count as hire days.

Calibration and checks

Supplied in working order with listed accessories, leads and manuals. Each measuring instrument is calibrated, and its current NATA-traceable calibration certificate is available on request. If calibration falls due during your hire, we tell you before dispatch.

Cancelling or moving a booking

Cancel 5 or more business days before dispatch or collection and nothing is charged. With 2 to 4 business days’ notice, the charge is the greater of one day’s hire and 5% of the booked hire; with less notice, the greater of one day’s hire and 10%. You can ask once to move the start by up to 30 days, with at least 2 business days’ notice.

Loss, damage and insurance

The equipment is your responsibility, other than fair wear and tear, from the start of hire until it is back with us, including in transit, up to the replacement value cap shown on the quote for each item. No damage waiver is offered. We recommend you insure the equipment for its replacement value.

Payment and bond

Account customers pay each invoice within 14 days. Without a credit account, or paying by card, you pay the booked hire, freight, handling fee and any bond before dispatch. A bond applies only where the quote states one, and is refunded after return and inspection, less anything owed.

Summary of our Terms and Conditions: Test Equipment Hire. Full hire terms

Enquire about Earth Testing Equipment Hire

Check availability

Send your hire dates and delivery location and we will confirm availability and lead time by the end of the next business day.

Or call us directly on 1300 730 499

Dates and alternatives
Delivery or collection

* Required. This asks for availability and a price; it does not reserve the equipment. We reply by the end of the next business day. Hire within Australia only.

Megavar Pty Ltd (ABN 88 104 344 765) collects these details to check availability, quote your hire, arrange delivery or collection and keep a record of it, and to understand how enquiries reach us. If you do not provide them we may not be able to quote. We may share them with our IT, email and business system providers, with freight carriers for delivery and collection, and, where relevant, our insurers and professional advisers, and some of those providers store or process information outside Australia, including in the United States. Our Privacy Policy explains how we handle your information and how to access or correct it or make a complaint.

Need help with your rental?
1300 730 499 We’re available Monday to Friday, 8:30 am to 5:00 pm. Urgent hire: call rather than send the form. rentals@megavar.com.au

FAQ

Frequently Asked Questions for Earth Test Equipment

What is earth grid impedance testing and when is it required?

Earth grid impedance testing measures the resistance of a substation’s earthing system to remote earth. It is required during commissioning of new substations, after earth grid extensions or modifications, and periodically to verify ongoing compliance with safety standards. Low earth grid impedance is essential to ensure fault currents are safely dissipated and that touch and step voltages remain within safe limits for personnel.

What are step and touch voltage measurements?

Step voltage is the potential difference between two points on the ground surface one metre apart (the distance of a normal step). Touch voltage is the potential difference between an earthed structure and a point on the ground one metre away. Both must remain below defined safety limits during an earth fault to protect personnel. Megavar’s CPC 100 + CP CU1 system measures actual step and touch voltages across the substation footprint during earth grid commissioning.

What standard applies to earthing system testing in Australia?

The primary references for earthing system design and testing in Australia are ENA EG-0 (Power System Earthing Guide, the risk framework) and ENA EG-1 (Substation Earthing Guide), read with AS 2067:2016 (Substations and high voltage installations exceeding 1 kV a.c.) and IEEE 80. Network owners such as ElectraNet and TasNetworks have additional site-specific earthing standards and testing requirements that we are familiar with.

Can Megavar perform earth grid testing on our behalf?

Yes. Megavar provides full earth grid testing services including earth grid impedance measurement, step and touch voltage surveys, soil resistivity surveys, and earth grid design review. Our engineers are experienced in testing earth grids on transmission, distribution, and industrial sites across Australia.

What test lead lengths are required for earth grid impedance testing?

Test lead lengths depend on the size of the earth grid being tested. As a general guide, the current injection electrode should be placed at a distance of at least 5 times the diagonal dimension of the earth grid from the grid perimeter. For large transmission substation earth grids, this can mean current injection leads of several hundred metres or more. Megavar supplies appropriate lead lengths based on your earth grid dimensions.

Explore Our Services

HV earthing design and testing. Earth grid design, soil resistivity, injection testing and step and touch surveys for substations across Australia.

HV substation maintenance across Australia. Preventive and condition-based programmes, protection testing and switchgear servicing from five offices.

High voltage testing and commissioning of substations, transformers, cables and switchgear by Megavar's own engineers, from five offices. Call 1300 730 499.

Trusted by top enterprises for exceptional results

AusNet logo - Megavar clientABB logo - Megavar clientElectraNet logo - Megavar clientFluence logo - Megavar clientRJE Global logo - Megavar clientNYRStar logo - Megavar clientSchneider Electric logo - Megavar clientAcciona logo - Megavar clientRBD Electrical logo - Megavar clientVentia logo - Megavar clientGrange logo - Megavar clientAlcoa logo - Megavar clientZinfra logo - Megavar client Bison Energy Company logo - Megavar client Hydro Tasmania logo - Megavar client TasNetworks logo - Megavar clientVestas logo - Megavar client Goldwind logo - Megavar client Downer logo - Megavar client ENERVEN logo - Megavar client Genus logo - Megavar client

Testing guides

Related testing guides

Earth Resistance Testing: Substation Earth Grids, Fall of Potential and Step and Touch Voltages

Earth resistance testing shows whether an earth electrode or substation earth grid will carry fault current safely into the ground. This guide explains the fall-of-potential method,…

Ductor Testing: A Field Guide to Contact Resistance Measurement on HV Plant

Ductor testing measures the resistance of circuit breaker contacts, busbar joints, cable lugs and earth bonds in micro-ohms. This guide explains the test current to use,…

Insulation Resistance Testing: A Field Guide to Megger Testing, PI and DAR on HV Plant

An insulation resistance test applies a steady DC voltage across insulation and measures the small current that flows. This guide explains the test voltage to use,…

All testing guides

8 instruments
Minimum hire one day
View instruments