Testing and commissioning services

SCADA & RTU Commissioning Services Australia 

Talk to an engineer: 1300 730 499 or service@megavar.com.au

Design, Configuration, Testing, and Commissioning of Substation Automation Systems


Modern substations depend on SCADA (Supervisory Control and Data Acquisition) systems for real-time monitoring, control, and data acquisition. Whether you are building a new substation, upgrading an ageing SCADA system, or integrating a renewable energy project into the grid, Megavar provides end-to-end SCADA engineering from design through to commissioning and ongoing support, including SCADA point-to-point verification as part of substation commissioning.


Our SCADA engineers possess a rare combination of power systems engineering knowledge and IT/communications expertise, enabling us to bridge the gap between operational technology (OT) and the increasingly connected digital substation environment.

ISO 9001, 14001 and 45001 certifiedLicensed in every Australian stateTeams in Hobart, Launceston, Adelaide and Newcastle
SCADA and RTU Commissioning Services Australia

SCADA Services We Provide

SCADA System Design and Architecture

System architecture design for substation SCADA, DMS (Distribution Management Systems), and EMS (Energy Management Systems). RTU and gateway specification. Communication network design (fibre, serial, Ethernet, 4G/5G failover). Integration architecture for multi-vendor environments.

RTU and Gateway Configuration

Configuration and parameterisation of RTUs and protocol gateways from all major manufacturers, including ABB RTU560/RTU500, Schneider Electric SCADAPack, GE D400/D25, SEL-3530 RTAC, Siemens SICAM, and Survalent. We configure all standard protocols: DNP3, IEC 60870-5-101/104, IEC 61850 MMS, Modbus TCP/RTU, and OPC-UA.

IEC 61850 Integration

Complete IEC 61850 substation automation including SCL file engineering, GOOSE messaging configuration, MMS data model setup, and IEC 61850 gateway configuration for legacy protocol conversion.

Cybersecurity

SCADA cybersecurity assessment and hardening aligned with the Australian Energy Sector Cyber Security Framework (AESCSF) and IEC 62351. Includes network segmentation, firewall rule development, intrusion detection, access control, patch management, and vulnerability assessment.

Testing and Commissioning

Factory acceptance testing (FAT) of SCADA systems, site acceptance testing (SAT), end-to-end communication verification, failover and redundancy testing, and performance validation.

Why Choose Megavar for SCADA Engineering and Integration?

  • Industry-Leading Renewable Energy & Utility SCADA Expertise: Trusted partner for solar farms, wind projects, and utility networks.
  • Comprehensive SCADA Integration Solutions: Full-service approach covering design, commissioning, and maintenance.
  • National Reach & Compliance Assurance: Supporting projects Australia-wide with full regulatory adherence.
  • Advanced System Security & Cyber Protection: Ensuring SCADA networks remain secure and resilient.

Partner with Megavar for SCADA Engineering and Integration that enhances your renewable energy and high-voltage operations. Contact us today! 

Take it to your team

Capability statement

Substation SCADA and Automation

SCADA and substation automation design, RTU and gateway configuration, IEC 61850 integration, OT cyber security, and FAT, SAT and point to point testing.

Capability statement

High-Voltage System Design

Primary, secondary, protection and SCADA design, with earthing, EMF and lightning protection modelling.

Clients

What our clients say

The Megavar team demonstrate professionalism and excellence in all aspects of HV electrical commissioning. It’s great to work with the team with the high standards of quality and safety that you would expect when dealing with complex high voltage installations, the experienced Megavar team has been exactly what was needed for project delivery.

Russell CunninghamCommissioning Manager | Fluence Energy

Megavar are industry leaders in HV commissioning services, offering high quality commissioning services. They are experts in high voltage commissioning services, and their work is always on time, on budget and to the highest quality.

Shaun ColtonEngineering Manager Substations & BESS, Downer Group

FAQ

Frequently Asked Questions SCADA Engineering and Integration Services

What SCADA protocols does Megavar support?

We support all standard substation communication protocols: DNP3 (serial and TCP/IP), IEC 60870-5-101 and 104, IEC 61850 (GOOSE, MMS, sampled values), Modbus TCP and RTU, and OPC-UA.

Does Megavar provide SCADA cybersecurity services?

Yes. We provide SCADA cybersecurity assessment and hardening aligned with the AESCSF and IEC 62351, including network segmentation, firewall configuration, vulnerability assessment, and penetration testing.

What RTU platforms does Megavar work with?

ABB RTU560/RTU500, Schneider Electric SCADAPack, GE D400/D25, SEL-3530 RTAC, Siemens SICAM, Survalent, and other platforms. We are vendor-agnostic.

Can Megavar integrate SCADA with AEMO and NSP control rooms?

Yes. A core part of our SCADA commissioning scope is end-to-end verification of data flow from substation to the NSP and AEMO control rooms, including failover and redundancy testing.

Does Megavar upgrade legacy SCADA systems?

Yes. We regularly upgrade and migrate legacy SCADA systems, including serial-to-IP protocol conversion, RTU replacement, and IEC 61850 retrofitting to older substations.

ISO Certified and Licensed in Every State

Megavar is certified to ISO 9001 (quality), ISO 14001 (environment) and ISO 45001 (safety), and holds electrical contractors licences in every Australian state.

Ready to commission your substation? Contact Megavar today on 1300 730 499 or visit our contact page to request a quote.

Contact Us

Request a quote

Tell us about the job

An engineer replies by the end of the next business day (Monday to Friday, 8:30 am to 5:00 pm). Scope still forming? Send what you have. Outage or urgent fault? Call to discuss the site, access window and mobilisation.

Scope status
Drag & Drop Files, Choose Files to Upload

* Required.

Megavar Pty Ltd (ABN 88 104 344 765) collects these details, and any file you attach, to prepare your quote, respond to your enquiry and keep a record of it, and to understand how enquiries reach us. If you do not provide them we may not be able to quote. We may share them with our IT, email and business system providers and, where relevant, our insurers and professional advisers, and some of those providers store or process information outside Australia, including in the United States. Our Privacy Policy explains how we handle your information and how to access or correct it or make a complaint.

Talk to us now
1300 730 499 service@megavar.com.au Hobart · Launceston · Adelaide · Newcastle · Gladstone
Doing it in-house?Hire relay test sets

Explore Our other services

Power transformer testing and commissioning across Australia. Ratio, winding resistance, SFRA, tan delta and oil diagnostics with a 200+ item test fleet.

Circuit breaker testing across Australia. Timing, travel, contact resistance and insulation diagnostics on HV breakers by Megavar commissioning engineers.

Protection relay testing and secondary injection across Australia. Schemes proven to specification by Megavar's commissioning engineers. Enquire today.

Trusted by top enterprises for exceptional results

AusNet logo - Megavar clientABB logo - Megavar clientElectraNet logo - Megavar clientFluence logo - Megavar clientRJE Global logo - Megavar clientNYRStar logo - Megavar clientSchneider Electric logo - Megavar clientAcciona logo - Megavar clientRBD Electrical logo - Megavar clientVentia logo - Megavar clientGrange logo - Megavar clientAlcoa logo - Megavar clientZinfra logo - Megavar client Bison Energy Company logo - Megavar client Hydro Tasmania logo - Megavar client TasNetworks logo - Megavar clientVestas logo - Megavar client Goldwind logo - Megavar client Downer logo - Megavar client ENERVEN logo - Megavar client Genus logo - Megavar client

Testing guides

Related testing guides

Secondary Isolation: CT Shorting Links, Test Blocks and Trip Isolation for Protection Testing

Secondary isolation separates the protection, control and metering circuits under test from the circuits that stay in service. This guide sets out the principles: CT shorting…

Protection Relay Testing: Secondary Injection, Test Intervals and the Standards That Apply

Protection relay testing proves that the relays guarding a substation, feeder or generator will trip when they should and stay stable when they should not. This…

Power Quality Testing: A Field Guide to Logging and Analysis at the Point of Connection

Power quality testing logs voltage and current at a point of connection for days and analyses the record for voltage, unbalance, harmonics, flicker, dips, swells, interruptions…

All testing guides

Testing services
Engineers Australia-wide
Request a quote