Protection Relay Testing Equipment for Hire
Day rates, 1 to 7 days, ex GST:
- Omicron CMC 356 Universal Relay Test Set$550
- Omicron CMC 500 Multi-Phase Relay Test Set$650
- Omicron CMGPS 588 GPS Synchronisation Unit$125
- Omicron CMLIB REF6xx Interface Adapter$125
Every rate band is on the instrument page. Minimum hire one day.
Megavar supplies a range of protection relay test equipment for hire, backed by engineers who use this equipment daily on live substation commissioning projects. Whether you need a full six-phase relay test set for complex distance protection schemes or an IEC 61850 test set for GOOSE testing, our rental fleet covers it.
Rates per day, ex GST
Omicron Equipment Available for Hire
Each instrument is supplied with its manuals. If one plays up, call us and we will arrange a fix or a replacement. No computer is supplied: where an instrument needs software, install it on your own computer.
Calibration
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Need High Voltage Testing or Equipment?
Tell us what you need and when, and we will come back with availability and pricing.
About protection relay testing equipment hire
Protection Relay Testing Equipment hire, in more detail
Introduction
Unlike pure rental companies, Megavar’s commissioning engineers use every piece of equipment we hire out. We also offer on-site commissioning support if needed.
All relay test sets are supplied calibrated, with test leads and accessories included, and current calibration certificates are available on request. Hire periods are flexible, from single-day hires for commissioning checks through to long-term project rentals. We deliver Australia-wide from our depots in Tasmania, South Australia and New South Wales.
Choosing between the two OMICRON relay test sets? See the CMC 356 vs CMC 500 comparison.
Why Hire Relay Test Equipment from Megavar?
Megavar is not just an equipment rental company: we are a specialist high-voltage testing and commissioning firm with over 20 years of experience. We maintain our fleet to the highest standards, with regular calibration and thorough pre-dispatch checks, so the equipment arrives ready to test.
Our team can also provide on-site commissioning support, protection relay testing services, and test plan development if you need more than just the equipment. With offices across Australia, we offer fast turnaround and competitive hire rates for both short-term and long-term rentals.
Before you get to site
Protection Relay Testing: Secondary Injection, Test Intervals and the Standards That Apply
A Megavar field guide to the test: what it proves, how it is set up and how to read the result.
Capability statement
Test Equipment Rental
The HV test equipment hire fleet by category, with calibration, hire terms and delivery.
How the hire works
Hire terms in brief
After you enquire
We confirm availability, rates and freight in a written quote, valid for the period it states (usually 14 days). An enquiry or quote does not reserve equipment: the hire is booked when your purchase order, signed quote or email acceptance reaches us.
Hire period
Our carrier: up to 72 hours of transit each way is not charged as hire. Hire starts at delivery or 72 hours after dispatch, whichever is earlier, and ends at handover to our carrier or 72 hours before the equipment arrives back, whichever is later. Delay caused by us or our carrier is not charged. For example, dispatched Monday 10am and delivered Wednesday 2pm: hire starts Wednesday 2pm. Routes that normally take longer than 72 hours are marked on the quote. Your own freight: hire runs from handover to your carrier at our office until the equipment arrives back at our office. Collect in person: from collection to return.
Extensions and early return
Contact us before the return deadline to extend; your quoted rates stay fixed and extended hire is invoiced every 7 days. Return early and you pay only for the days used, at the rate band for the days actually hired.
Delivery and returns
Freight for each leg, the handling fee and any express dispatch are on the quote, before you accept. Returns go to the dispatching office named on the quote, by carrier or in person, never by post.
Counter times
Returned to our counter before 9am on a business day counts as the previous day. Collected after 4pm on a business day, hire starts the next day. Weekends and public holidays count as hire days.
Calibration and checks
Supplied in working order with listed accessories, leads and manuals. Each measuring instrument is calibrated, and its current NATA-traceable calibration certificate is available on request. If calibration falls due during your hire, we tell you before dispatch.
Cancelling or moving a booking
Cancel 5 or more business days before dispatch or collection and nothing is charged. With 2 to 4 business days’ notice, the charge is the greater of one day’s hire and 5% of the booked hire; with less notice, the greater of one day’s hire and 10%. You can ask once to move the start by up to 30 days, with at least 2 business days’ notice.
Loss, damage and insurance
The equipment is your responsibility, other than fair wear and tear, from the start of hire until it is back with us, including in transit, up to the replacement value cap shown on the quote for each item. No damage waiver is offered. We recommend you insure the equipment for its replacement value.
Payment and bond
Account customers pay each invoice within 14 days. Without a credit account, or paying by card, you pay the booked hire, freight, handling fee and any bond before dispatch. A bond applies only where the quote states one, and is refunded after return and inspection, less anything owed.
Summary of our Terms and Conditions: Test Equipment Hire. Full hire terms
Enquire about Protection Relay Testing Equipment Hire
Check availability
Send your hire dates and delivery location and we will confirm availability and lead time by the end of the next business day.
Or call us directly on 1300 730 499
Need help with your rental?
1300 730 499 We’re available Monday to Friday, 8:30 am to 5:00 pm. Urgent hire: call rather than send the form. rentals@megavar.com.auFAQ
Frequently Asked Questions for Protection Relay Test Equipment
What is the difference between the Omicron CMC 356 and CMC 500 for relay testing?
Can I hire a relay test set for just one day?
Do you provide test leads and accessories with the relay test set hire?
Can Megavar help during my relay testing project?
What types of protection relays can I test with your hire equipment?
Do you deliver relay test equipment Australia-wide?
Explore Our Services
Trusted by top enterprises for exceptional results



Testing guides
Related testing guides
Protection Relay Testing: Secondary Injection, Test Intervals and the Standards That Apply
Protection relay testing proves that the relays guarding a substation, feeder or generator will trip when they should and stay stable when they should not. This…
Secondary Isolation: CT Shorting Links, Test Blocks and Trip Isolation for Protection Testing
Secondary isolation separates the protection, control and metering circuits under test from the circuits that stay in service. This guide sets out the principles: CT shorting…
CT Testing: A Field Guide to Ratio, Polarity, Excitation and Burden Tests on Current Transformers
CT testing proves that a current transformer has the ratio and polarity on its nameplate, a healthy magnetic core and sound secondary insulation. This guide explains…
Minimum hire one day View instruments