TM1600 Circuit Breaker Test Set. Hire from Megavar for timing, travel and dynamic resistance testing of HV circuit breakers across Australia.
Description
The TM1600 is a powerful and highly configurable circuit breaker timing analyser designed for precise timing measurements on medium- and high-voltage circuit breakers. Manufactured by Megger (formerly Programma), it provides accurate results for trip/open, close, and bounce times, as well as auxiliary contact behaviour and breaker sequence timing. The TM1600 supports testing of single- or three-phase breakers, including those with simultaneous or independent pole operation. Its modular design allows expansion with additional timing, motion, or coil current channels, making it a trusted platform for factory acceptance, commissioning, and maintenance testing of all circuit breaker types.

• Measures opening, closing, bounce, and reclosing times
• Supports both single-pole and three-pole circuit breakers
• Time resolution better than 0.1 ms
• Records auxiliary contact performance (52a, 52b, trip, close)
• Optional modules for motion/transducer and coil current analysis
• Expandable channel configuration based on application
• Built-in printer and onboard storage (depending on model)
• User-friendly interface with dedicated timing menus
• Durable flight case housing for field and workshop use
• Supplied with timing cables, test leads, clamps, and manuals

No content available.
No content available.
No content available.
Hiring for 3, 6, or 12 months? Call for project rates: 1300 730 499

Enquire about Megger TM1600 Circuit Breaker Analyser Hire

Tell us about your project and we will get back to you within 24 hours with availability and a quote.

Or call us directly on 1300 730 499

Need help with your rental?

We’re available Mon – Fri 8am – 5pm

Australian engineering team
Calibrated and traceable to NMI
Pre-hire briefing on every order
Australia-wide delivery

Megavar engineers use this unit on commissioning projects across Australia. Hire it from a team that knows it inside out.

Calibration

All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.

Ask an Engineer

Have a setup or application question about this instrument? Talk directly to a Megavar commissioning engineer — no call centre, no guesswork.

1300 730 499

Related Equipment For Hire

Frequently Asked Questions
Megger TM1600 Circuit Breaker Analyser

What does the TM1600 measure?

It measures the opening and closing times of a circuit breaker’s main contacts, bounce times, reclosing intervals, and auxiliary contact performance (such as 52a and 52b sequences).

Yes. It supports both single-pole and three-pole timing. You can test all three poles simultaneously or independently, depending on breaker configuration.

Yes. With optional coil current clamps and modules, the TM1600 can capture trip and close coil current profiles, useful for diagnostic analysis.

No. Unlike CIBANO 500, the TM1600 typically requires at least one side of the breaker to be isolated from ground for accurate timing.

Motion analysis is supported via additional transducer modules and accessories (not always included as standard). Please enquire if travel testing is required.

Most TM1600 units include either an onboard display or legacy PC connection. For advanced reporting, external software options may be provided (based on your rental configuration).

• TM1600 base unit
• Timing cables and test leads
• Coil control leads and contact sense inputs
• Carry case and printed operation manual
• (Optional) coil current probes, motion sensors (by request)

Yes. We offer remote support for system setup, connection diagrams, test interpretation, and best practices for safe operation.

The minimum hire period is 3 days, with weekly and monthly discounts available for longer projects.

Yes. We offer door-to-door delivery across Australia or can coordinate with your preferred freight provider.

A Tailored Hire Experience That Works for You

At Megavar, our dedicated test equipment hire division provides high-quality electrical testing instruments for both short and long-term use. Backed by deep industry expertise, our team ensures you receive the right tools with the right advice, every time. From fast dispatch to full technical support, our hiring process is streamlined to get you up and running quickly and confidently.
 
  • Rapid delivery and collection
  • Door-to-door freight for minimal downtime
  • Fast, simple bookings
  • Place an order and we’ll handle the rest
  • Rent, try or buy
  • Test the equipment before committing to purchase
  • Expert support
  • Technical help is just a call away when you need it.

Our 3-step easy process

Hiring Made Easy in 3 Simple Steps

Step 1: Request a Quote

Submit your rental request online, and our team will respond promptly with availability, pricing, and expert advice.

Step 2: Organise Your Rental

Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.

Step 3: Use with Confidence

Get to work with reliable, industry-grade test equipment. Our technical team is available to support you every step of the way.

Explore Our Services

HV earthing design and testing: earth grid design, EPR calculations, step and touch voltage analysis, soil resistivity surveys, and compliance testing per ENA EG-0 across Australia.

SCADA engineering and integration for substations and renewable energy projects. RTU configuration, IEC 61850, DNP3, cybersecurity, and end-to-end commissioning across Australia.

Arc flash studies and hazard analysis across Australia: incident energy and arc flash boundary calculation to IEEE 1584, PPE and labelling, and mitigation design.

Trusted by top enterprises for exceptional results

AusNet logo - Megavar client
ABB logo - Megavar client
ElectraNet logo - Megavar client
Fluence logo - Megavar client
RJE Global logo - Megavar client
NYRStar logo - Megavar client
Schneider Electric logo - Megavar client
Acciona logo - Megavar client
RBD Electrical logo - Megavar client
Ventia logo - Megavar client
Grange logo - Megavar client
Alcoa logo - Megavar client
Zinfra logo - Megavar client
Bison Energy Company logo - Megavar client
Hydro Tasmania logo - Megavar client
TasNetworks logo - Megavar client
Vestas logo - Megavar client
Goldwind logo - Megavar client
Downer logo - Megavar client
ENERVEN logo - Megavar client
Genus logo - Megavar client

Explore the latest insights