HVA / b2 HV Test Equipment · Cable testing
HVA 60kV VLF Cable Test Set
$450 per day ex GST, 1 to 7 days
Per day, AUD ex GST. The rate for your total hire length applies to every day, and the total never drops at a band change. Minimum hire one day. Australia-only hire; freight and handling quoted separately. Hiring for more than 90 days? Call for a long-term rate: 1300 730 499
Work out your hire
Pick your first and last day to see the hire charge.
| 7 days | $3,150 |
|---|---|
| 14 days | $5,670 |
| 28 days | $9,450 |
| 60 days | $17,010 |

- Delivery or collection
- Freight Australia-wide, quoted with availability, or collect from Hobart, Launceston, Adelaide or Newcastle. Urgent? Call 1300 730 499 rather than send the form.
- Datasheet
- Manufacturer's datasheet (PDF). Calibration certificate supplied with the instrument.
Overview
About the HVA 60kV VLF Cable Test Set
Description
The HVA 60 is a high-performance Very Low Frequency (VLF) test set designed for testing high-voltage cables, rotating machinery, switchgear, and other dielectric systems rated up to 36 kV. It delivers a true sinusoidal AC output at 0.1 Hz and provides reliable withstand testing for both new installations and periodic maintenance. With its lightweight, portable design and intuitive controls, the HVA 60 is ideal for field use in substations, power plants, industrial facilities, and utility networks. Built-in memory and USB connectivity ensure easy data capture, and optional accessories expand its functionality with diagnostics such as Tan Delta and Partial Discharge.
Features
• VLF test output up to 60 kV peak (42 kV RMS)
• Suitable for MV and HV cables rated up to 36 kV
• True 0.1 Hz sinusoidal waveform for standard-compliant testing
• Fully automatic test sequences and manual mode options
• Robust and portable design – only ~29 kg total weight
• Output modes include VLF, DC+, DC–, and sheath testing
• Built-in memory with USB port for easy data export
• Optional Tan Delta and Partial Discharge add-ons (if applicable)
• Intuitive menu system with high-contrast display
• Supplied with HV test leads, ground cable, and hard carry case
What’s in the case
- HVA 60 test unit
- HV output cable
- Ground cable
- Standard accessories
- Carry case
Calibration
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Often hired with
Related Equipment For Hire
PFISTERER CONNEX Grounding and Current Testing Connector (Size 0) for Hire
From $60 per day
View Hire DetailsWhy hire from Megavar
A Tailored Hire Experience That Works for You
At Megavar, our dedicated test equipment hire division provides high-quality electrical testing instruments for both short and long-term use. Our team makes sure you receive the right tools, ready to go, every time. From fast dispatch to door-to-door freight, our hiring process is streamlined to get you up and running quickly and confidently.
- Rapid delivery and collectionDoor-to-door freight for minimal downtime
- Fast, simple bookingsPlace an order and we’ll handle the rest
- Fault supportIf a set plays up, call us and we will arrange a fix or a replacement.
Our 3-step easy process
Hiring Made Easy in 3 Simple Steps
Step 1: Request a Quote
Submit your rental request online, and our team will respond promptly with availability and pricing.
Step 2: Organise Your Rental
Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.
Step 3: Use with Confidence
Supplied with the manufacturer’s manuals. If a set plays up, call us and we will arrange a fix or a replacement.
How the hire works
Hire terms in brief
After you enquire
We confirm availability, rates and freight in a written quote, valid for the period it states (usually 14 days). An enquiry or quote does not reserve equipment: the hire is booked when your purchase order, signed quote or email acceptance reaches us.
Hire period
Our carrier: up to 72 hours of transit each way is not charged as hire. Hire starts at delivery or 72 hours after dispatch, whichever is earlier, and ends at handover to our carrier or 72 hours before the equipment arrives back, whichever is later. Delay caused by us or our carrier is not charged. For example, dispatched Monday 10am and delivered Wednesday 2pm: hire starts Wednesday 2pm. Routes that normally take longer than 72 hours are marked on the quote. Your own freight: hire runs from handover to your carrier at our office until the equipment arrives back at our office. Collect in person: from collection to return.
Extensions and early return
Contact us before the return deadline to extend; your quoted rates stay fixed and extended hire is invoiced every 7 days. Return early and you pay only for the days used, at the rate band for the days actually hired.
Delivery and returns
Freight for each leg, the handling fee and any express dispatch are on the quote, before you accept. Returns go to the dispatching office named on the quote, by carrier or in person, never by post.
Counter times
Returned to our counter before 9am on a business day counts as the previous day. Collected after 4pm on a business day, hire starts the next day. Weekends and public holidays count as hire days.
Calibration and checks
Supplied in working order with listed accessories, leads and manuals. Each measuring instrument is calibrated, and its current NATA-traceable calibration certificate is available on request. If calibration falls due during your hire, we tell you before dispatch.
Cancelling or moving a booking
Cancel 5 or more business days before dispatch or collection and nothing is charged. With 2 to 4 business days’ notice, the charge is the greater of one day’s hire and 5% of the booked hire; with less notice, the greater of one day’s hire and 10%. You can ask once to move the start by up to 30 days, with at least 2 business days’ notice.
Loss, damage and insurance
The equipment is your responsibility, other than fair wear and tear, from the start of hire until it is back with us, including in transit, up to the replacement value cap shown on the quote for each item. No damage waiver is offered. We recommend you insure the equipment for its replacement value.
Payment and bond
Account customers pay each invoice within 14 days. Without a credit account, or paying by card, you pay the booked hire, freight, handling fee and any bond before dispatch. A bond applies only where the quote states one, and is refunded after return and inspection, less anything owed.
Summary of our Terms and Conditions: Test Equipment Hire. Full hire terms
Enquire about HVA 60kV VLF Cable Test Set Hire
When and where do you need it?
Send your hire dates and delivery location and we will confirm availability and lead time by the end of the next business day.
Or call us directly on 1300 730 499
Need help with your rental?
1300 730 499 We’re available Monday to Friday, 8:30 am to 5:00 pm. Urgent hire: call rather than send the form. rentals@megavar.com.auQuestions about this hire?
Call 1300 730 499 for availability, rates and booking. If a set plays up during the hire, call us and we will arrange a fix or a replacement. Counter collection and returns 8:30 am to 5:00 pm, Monday to Friday.
FAQ
Frequently Asked Questions
HVA 60kV VLF Cable Test Set
What is the HVA 60 used for?
The HVA 60 performs high-voltage VLF withstand tests on medium- and high-voltage cables, switchgear, and rotating machinery. It helps verify insulation integrity before or after installation, repair, or maintenance.
What systems can it test?
It is suitable for testing cables rated up to 36 kV, including XLPE, PILC, and EPR-insulated cables, as well as transformers, motors, and switchgear insulation.
What’s the output voltage and waveform?
The unit delivers up to 60 kV peak (42 kV RMS) at 0.1 Hz with a true sinusoidal waveform, in compliance with IEC and IEEE testing standards.
Does it support diagnostic testing?
Yes. The HVA 60 can be used with optional add-ons to perform Tan Delta (TD) and Partial Discharge (PD) testing, depending on your configuration.
Can I store and export test results?
Yes, the instrument includes internal memory and USB connectivity for easy data download and reporting.
Is the unit easy to transport?
Yes. Despite its high voltage output, the HVA 60 is housed in a compact, lightweight, and rugged case suitable for tough field environments.
What’s included in the rental?
The rental includes the HVA 60 test unit, HV output cable, ground cable, standard accessories, and a carry case.
What support comes with the hire?
Each instrument is supplied with the manufacturer’s manuals. If a set plays up, call us and we will arrange a fix or a replacement.
How do I request a quote or arrange a hire?
Complete the quote form on this page with your project details and preferred dates. We’ll confirm availability and provide a quote promptly.
Do you deliver Australia-wide?
Yes. We offer national delivery and pickup services. You may also organise your own freight if preferred.
Explore Our Services
Trusted by top enterprises for exceptional results



ex GST, 1 to 7 days Check availability