Megavar delivered HV testing and protection system commissioning for the Bluegrass BESS (Blue Grass) project in Queensland's Western Downs, working in partnership with
• Output voltage up to 50 kV AC at 60 mA
• Designed for dielectric withstand (hipot) testing
• Separate high-voltage and control units for operator safety
• Manual voltage control with smooth regulation
• Zero start interlock and overload protection
• Built-in metering for output voltage and leakage current
• Suitable for testing switchgear, cables, motors, insulators, bushings, and more
• Rugged enclosure with HV output lead and ground cable
• Air-insulated construction for compact portability
• Supplied with control unit, HV tank, cables, and transport case
Tell us about your project and we will get back to you within 24 hours with availability and a quote.
Or call us directly on 1300 730 499
We’re available Mon – Fri 8am – 5pm
Megavar engineers use this unit on commissioning projects across Australia. Hire it from a team that knows it inside out.
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Have a setup or application question about this instrument? Talk directly to a Megavar commissioning engineer — no call centre, no guesswork.
It is used for AC dielectric withstand testing (hipot) to verify the insulation strength of electrical equipment by applying high voltage for a specified duration and checking for breakdown.
It can output up to 50 kV AC at a maximum of 60 mA, which is suitable for a wide range of MV/HV insulation systems.
Yes. It is suitable for withstand testing in accordance with standards like IEC 60060, IEEE 4, and ANSI/NETA ATS.
It’s ideal for high-voltage power cables, motors, switchgear, transformers, rotating machines, insulators, and bushings.
Yes. It is field-portable with a rugged design and consists of two components: the control unit and the high-voltage tank.
It operates on standard single-phase mains power (typically 120V or 240V depending on model configuration). Check the datasheet or request assistance for your site voltage.
The 6CP50 includes zero-start interlock, overload protection, HV-on indicators, and a grounded control section for operator safety.
The rental includes the HV tank, control unit, HV output cable, ground cable, interconnect cable, and carry case. Test leads and accessories can be included as required.
Yes. We offer assistance with setup, operation, and interpreting test procedures throughout the rental period.
The standard minimum hire is 3 days, with weekly and monthly discounts available.
Submit your rental request online, and our team will respond promptly with availability, pricing, and expert advice.
Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.
Get to work with reliable, industry-grade test equipment. Our technical team is available to support you every step of the way.
We’re incredibly excited to share a big milestone in Megavar’s story—we’ve officially opened our new Newcastle branch, located at 22 Gavey Street, Mayfield,