Megavar delivered HV testing and protection system commissioning for the Bluegrass BESS (Blue Grass) project in Queensland's Western Downs, working in partnership with
• Output voltage up to 130 kV AC, 10 mA
• Suitable for dielectric withstand (hipot) testing of HV assets
• Two-piece design with separate control and HV units
• Smooth manual voltage control with zero start interlock
• Accurate metering of voltage and leakage current
• Overload and short-circuit protection for safe operation
• Ideal for testing HV cables, GIS, switchgear, bushings, motors, and transformers
• Air-insulated, rugged construction for outdoor and substation use
• Supplied with HV output lead, grounding lead, and transport case
Tell us about your project and we will get back to you within 24 hours with availability and a quote.
Or call us directly on 1300 730 499
We’re available Mon – Fri 8am – 5pm
Megavar engineers use this unit on commissioning projects across Australia. Hire it from a team that knows it inside out.
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Have a setup or application question about this instrument? Talk directly to a Megavar commissioning engineer — no call centre, no guesswork.
The BK130 is used for AC dielectric withstand (hipot) testing, applying high voltage to confirm the insulation strength of electrical components such as cables, switchgear, and transformers.
It can deliver up to 130,000 volts AC at a maximum current of 10 mA, suitable for testing high-voltage installations and components
It is ideal for power cables, transformers, switchgear, motors, rotating machines, bushings, insulators, and GIS assemblies.
Yes. It is suitable for withstand testing in accordance with IEC 60060, IEEE 4, IEEE C57.12.90, and other insulation testing standards.
Yes. It features a two-piece design with a grounded control unit separate from the HV tank, plus safety features like overload protection, HV-on indicators, and interlocks.
The rental includes the BK130 high-voltage tank, control unit, interconnecting cables, HV output cable, earth lead, and transport/storage case.
Yes. We provide remote support for setup, operation, and test procedure guidance throughout your hire period.
The minimum rental period is 3 days. We offer discounted weekly and monthly hire rates for longer projects.
Yes. We provide nationwide delivery and pickup. You may also arrange your own freight if preferred.
A security deposit may apply. For high-voltage test sets like this, we may request proof of business insurance. All conditions are provided in your quote.
Submit your rental request online, and our team will respond promptly with availability, pricing, and expert advice.
Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.
Get to work with reliable, industry-grade test equipment. Our technical team is available to support you every step of the way.
We’re incredibly excited to share a big milestone in Megavar’s story—we’ve officially opened our new Newcastle branch, located at 22 Gavey Street, Mayfield,