Mitton Instruments TVM1100 Tuned Voltmeter for Hire

From $85 (AUD ex GST per day. Weekly and monthly rates available.)

Tier 1: 1-7 days
$85 (AUD ex GST)
Tier 2: 8-14 days
$76.5 (AUD ex GST)
Tier 3: 15-28 days
$63.75 (AUD ex GST)
Tier 4: 29-90 days
$53.55 (AUD ex GST)
Mitton Instruments TVM1100 tuned voltmeter available for hire from Megavar Australia
Description
The Mitton TVM1100 has been specifically designed to accompany the LCI2000C injection unit, though it can be used for the measurement of voltages associated with any off-frequency current injection test. With its excellent noise rejection, the instrument measures the often very small voltages associated with injection testing of large earthing systems, even where power system frequency noise dominates. Hire the TVM1100 from Megavar for earth grid performance testing. The instrument is equipped with a full range high input impedance voltage measurement channel to ensure accurate prospective voltage measurements, and a second channel designed as the input for a flexible or clamp CT. Current and voltage measurements can be displayed simultaneously along with the applicable phase shift, which is what makes it useful for current split and grid impedance work rather than voltage measurement alone. It uses digital signal processing and can be tuned from 45 Hz to 65 Hz in 1 Hz steps, locking to the injected test frequency and rejecting power frequency noise at better than 70 dB. An intuitive user interface, colour LCD screen, GPS tracking and measurement data logging make fall of potential and other measurements paper-free.
  • Specifically designed to accompany the LCI2000C injection unit, and usable with any off-frequency injection test
  • Two channels with phase angle measurement to plus or minus 180 degrees
  • Tunable 45 Hz to 65 Hz in 1 Hz steps
  • Noise rejection better than 70 dB, greater than 3,000 to 1, at 50 Hz and 60 Hz
  • Channel 1 auto-ranging: 0 to 6 V, 0 to 60 V, 0 to 300 V
  • Channel 2 input for flexible or clamp CT
  • Ultra high sensitivity GPS at minus 165 dBm
  • Internal memory for measurement data logging
  • Trans-reflective colour LCD, readable in daylight
  • Battery life 8 to 16 hours on 3.7 V lithium ion

Specifications

  • Manufacturer: Mitton Instruments Ltd, Christchurch, New Zealand
  • Model: TVM1100
  • Channel 1, voltage: 0 to 6.0 Vrms (100 µV), 0 to 60 Vrms (1 mV), 0 to 300 Vrms (10 mV), auto-ranging
  • Channel 2, current input: 0 to 3.0 Vrms, resolution 100 µV
  • Phase angle: plus or minus 180 degrees
  • Accuracy: plus or minus 0.5% of full scale deflection, plus or minus 2 counts
  • Frequency lock: 45 to 65 Hz in 1 Hz steps, plus or minus 1 Hz
  • Input impedance, voltage: 2 megohm, or 1 kilohm in LOW Z mode
  • Input impedance, current: 94 kilohm
  • Noise rejection: Better than 70 dB, greater than 3,000 to 1, at 50 Hz and 60 Hz
  • GPS: ultra high sensitivity, minus 165 dBm
  • Memory: internal storage for data logging
  • Display: trans-reflective colour LCD
  • Battery: two 3.7 V lithium ion NCR18650 cells, 8 to 16 hours
  • Charging: 12 V DC, 2 A
  • Operating temperature: 0 to 40 degrees Celsius
  • Weight: 200 g
  • Dimensions: 210 mm high x 100 mm wide x 32 mm deep

Used for earth grid performance assessment by off-frequency current injection, including fall of potential earth impedance measurement, step and touch voltage measurement, ground potential rise assessment, current split measurement and transferred potential investigation. Applied on transmission and distribution substations, power stations and industrial facilities where accurate earth grid voltage measurement is required in the presence of dominant power frequency noise.

  • Mitton Instruments TVM1100 tuned voltmeter
  • Test leads and voltage probes
  • Charger, 12 V DC 2 A
  • Carry case

Download the TVM1100/LCI2000C MANUAL (PDF)

Off-frequency injection testing is core work for Megavar, not an occasional job, and we run the TVM1100 and LCI2000C together on substation earthing assessments regularly. We will advise on test setup, electrode and traverse placement, and interpretation against AS 2067 and IEEE Std 80, which on earthing work is usually worth more than the instrument itself.

Hiring for 3, 6, or 12 months? Call for project rates: 1300 730 499

Enquire about Mitton Instruments TVM1100 Tuned Voltmeter for Hire Hire

Tell us about your project and we will get back to you within 24 hours with availability and a quote.

Or call us directly on 1300 730 499

Need help with your rental?

We’re available Mon – Fri 8am – 5pm

Australian engineering team
Calibrated and traceable to NMI
Pre-hire briefing on every order
Australia-wide delivery

Megavar engineers use this unit on commissioning projects across Australia. Hire it from a team that knows it inside out.

Calibration

All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.

Ask an Engineer

Have a setup or application question about this instrument? Talk directly to a Megavar commissioning engineer — no call centre, no guesswork.

1300 730 499

Frequently Asked Questions
Mitton Instruments TVM1100 Tuned Voltmeter for Hire

What is the Mitton TVM1100 tuned voltmeter used for?

Measuring the small voltages produced during off-frequency current injection testing of earthing systems: fall of potential earth impedance, step and touch voltage, ground potential rise, current split and transferred potential. It is designed to accompany the Mitton LCI2000C injection unit but works with any off-frequency injection test.

Digital. It uses digital signal processing, locks to the injected test frequency anywhere from 45 Hz to 65 Hz in 1 Hz steps, and rejects power frequency noise at better than 70 dB, greater than 3,000 to 1, at 50 Hz and 60 Hz. It has a trans-reflective colour LCD, internal data logging and GPS.

Channel 1 is a high input impedance voltage channel, auto-ranging across 0 to 6 V, 0 to 60 V and 0 to 300 V. Channel 2 accepts a flexible or clamp CT, so current and voltage are displayed together with the phase angle between them. That is what makes current split and grid impedance measurement possible with one instrument.

Plus or minus 0.5 percent of full scale deflection, plus or minus 2 counts, per the manufacturer manual, Section 7.11. Filter accuracy depends on input conditions, and high noise levels may cause the instrument to select a higher range. Frequency lock is plus or minus 1 Hz.

Two 3.7 V lithium ion NCR18650 cells give 8 to 16 hours of operation. A 12 V DC 2 A charger is supplied with the hire. Operating temperature is 0 to 40 degrees Celsius.

The Mitton Instruments TVM1100 tuned voltmeter, test leads and voltage probes, the 12 V DC charger and a carry case. Megavar runs the TVM1100 and LCI2000C together on substation earthing assessments and can advise on traverse placement and interpretation against AS 2067 and IEEE Std 80.

A Tailored Hire Experience That Works for You

At Megavar, our dedicated test equipment hire division provides high-quality electrical testing instruments for both short and long-term use. Backed by deep industry expertise, our team ensures you receive the right tools with the right advice, every time. From fast dispatch to full technical support, our hiring process is streamlined to get you up and running quickly and confidently.
 
  • Rapid delivery and collection
  • Door-to-door freight for minimal downtime
  • Fast, simple bookings
  • Place an order and we’ll handle the rest
  • Rent, try or buy
  • Test the equipment before committing to purchase
  • Expert support
  • Technical help is just a call away when you need it.

Our 3-step easy process

Hiring Made Easy in 3 Simple Steps

Step 1: Request a Quote

Submit your rental request online, and our team will respond promptly with availability, pricing, and expert advice.

Step 2: Organise Your Rental

Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.

Step 3: Use with Confidence

Get to work with reliable, industry-grade test equipment. Our technical team is available to support you every step of the way.

Explore Our Services

Power system studies: load flow, short circuit, protection coordination, harmonic analysis, arc flash, and earthing studies. Supporting HV design, compliance, and grid connections across Australia.

Protection relay testing and secondary injection across Australia. Schemes proven to specification by Megavar's commissioning engineers. Enquire today.

BESS maintenance and testing across Australia. Keep your battery energy storage system safe, available and performing with Megavar. Enquire today.

Trusted by top enterprises for exceptional results

AusNet logo - Megavar client
ABB logo - Megavar client
ElectraNet logo - Megavar client
Fluence logo - Megavar client
RJE Global logo - Megavar client
NYRStar logo - Megavar client
Schneider Electric logo - Megavar client
Acciona logo - Megavar client
RBD Electrical logo - Megavar client
Ventia logo - Megavar client
Grange logo - Megavar client
Alcoa logo - Megavar client
Zinfra logo - Megavar client
Bison Energy Company logo - Megavar client
Hydro Tasmania logo - Megavar client
TasNetworks logo - Megavar client
Vestas logo - Megavar client
Goldwind logo - Megavar client
Downer logo - Megavar client
ENERVEN logo - Megavar client
Genus logo - Megavar client

Explore the latest insights