Megavar delivered HV testing and protection system commissioning for the Bluegrass BESS (Blue Grass) project in Queensland's Western Downs, working in partnership with
• Delivers up to 1.5 kVA injection power
• Injection current typically up to 25 A at low voltage (depending on load)
• Consists of 4023 (control unit) and 4024B (injection transformer)
• Suitable for earth grid integrity checks, fault path verification, and relay testing
• True RMS metering of voltage and current
• Smooth manual voltage control with overload protection
• Output tap selection for optimised injection based on site conditions
• Compact and rugged design for field use
• Supplied with heavy-duty test leads and transport case
Tell us about your project and we will get back to you within 24 hours with availability and a quote.
Or call us directly on 1300 730 499
We’re available Mon – Fri 8am – 5pm
Megavar engineers use this unit on commissioning projects across Australia. Hire it from a team that knows it inside out.
All Megavar test equipment is maintained under a documented calibration programme. Instruments are calibrated either by external calibration laboratories or in-house against reference standards that are themselves laboratory-calibrated, with measurement traceable to Australian national measurement standards held by the National Measurement Institute. A current calibration certificate is available on request. If your project requires a specific calibration interval, test standard, or documentation for a client submission, tell us at enquiry on 1300 730 499 and we will confirm what applies before you commit.
Have a setup or application question about this instrument? Talk directly to a Megavar commissioning engineer — no call centre, no guesswork.
From $85 per day
View Hire Details
From $125 per day
View Hire DetailsIt’s designed for earth injection testing, which involves injecting current into an earthing system and measuring the response to assess grid integrity and simulate fault conditions for protection testing.
Yes. The unit can simulate earth fault conditions, making it suitable for testing earth fault relays, residual current relays, and verifying pickup thresholds.
It can inject up to 25 A, depending on output voltage and site load impedance. It’s designed for low-impedance, high-current injection typical of substation grounding systems.
• The 4023 is the control unit, allowing voltage adjustment, metering, and overload protection
• The 4024B is the injection transformer, stepping down the voltage to provide high current output
Yes. Both units are compact, ruggedised, and supplied in a transportable configuration suitable for field deployment in substations and switchyards.
• Substation earth grid continuity and impedance checks
• Verification of fault current paths
• Relay pickup point testing
• Current distribution across earth electrodes or structures
• 4023 control unit and 4024B injection transformer
• Power and interconnect cables
• Heavy-duty output leads and clamps
• Operation manual and transport case
Yes. We offer remote support and test connection guidance, particularly helpful for earth injection setups which vary by site.
Standard minimum rental is 3 days, with weekly and monthly hire options available.
Yes. We provide nationwide delivery and collection, or you can arrange your own freight.
Submit your rental request online, and our team will respond promptly with availability, pricing, and expert advice.
Once confirmed, we’ll quickly process your booking and dispatch the equipment. Delivery and collection can be arranged to suit your schedule.
Get to work with reliable, industry-grade test equipment. Our technical team is available to support you every step of the way.
We’re incredibly excited to share a big milestone in Megavar’s story—we’ve officially opened our new Newcastle branch, located at 22 Gavey Street, Mayfield,